Origin |
China |
Model Number |
SAT-1AS |
◆ General
SAT-1AS Series 2M Transmission Analyzers is mainly used for measuring of the error rate of data communication and for the analysis of line fault and causes, and very suitable for the parameter measurement and routine maintenance testing of 2M system, N×64K communication channels.
◆ Major Features
·Chinese menu. Large screen. Easy operation.
·Multitask operation (It is allowed to conduct a test while browsing previous records).
·As many as 9 test settings and 20 groups of test results can be stored, and kept in memory in the event of power failure. .
·Communication with a PC is available to allow test data storage, analysis and printing to be carried out on the PC, or directly connected to a micro printer.
·The instrument can be powered on or off at certain times for testing purpose.
·Column diagram analysis of alarms and error codes;
·Software updating online.
◆ Main Functions
·Service-interrupted error code testing;
·Error code testing online;
·Framing and non-framing signals generation and reception;
·2 Mbit/s non-framing error code performance testing;
·2 Mbit/s framing N×64kbit/s channel error code performance testing;
·Performance testing of bit error, coding error, frame error, CRC error and E bit error;
·Alarm testing of signal loss, AIS alarm, frame remote alarm, multiframe remote alarm, out-of-frame, and out-of-pattern synchronism
·Frequency swing testing;
·Line signal frequency testing;
·Speech channel signal level and frequency testing;
·Pattern slip testing;
·Straightforward signaling
·Audio frequency testing;
·Sound monitoring;
·Signaling state display. Voice channel content display. Voice channel busy indication;
·Column diagram analysis of alarms and error codes;
·Time sot content analysis;
·Frame content analysis;
·G. 821/G. 826/M. 2100 error code performance analysis;
·Several kinds of error code and alarm insertion;
·Three input modes (terminating, bridging and monitoring);
·Two clock options (internal and picking-up);
·RS-232 interface for printing result;
◆ Technical Index
·2M Technical Index
(1) Signal input rate: 2048kbit/s±100ppm(G.703 requirement±50PPM)
(2) Signal coding: HDB3, AMI.
(3) Input jitter tolerance: Up to the requirement of Figure 10.1.
(4) Input balance response: Attenuation complies with the law of square root of frequency, and is within the range of 0 to 6dB at 1024 kHz.
(5) Input Impedance
(5.1) Unbalance terminating: 75Ω
Balance terminating: 120Ω.
Reflection loss >18dB within 50Hz~3100kHz.
(5.2) Unbalance bridging: >750Ω Balance bridging: >1200Ω
(5.3) Unbalance monitoring: 75Ω, 26dB gain
Balance monitoring: 120Ω, 26dB gain
Reflection loss >18dB within 50Hz~3100kHz.
(6) Signal structure
(6.1) Non-frame structure
(6.2) Frame structure: PCM30, PCM31, PCM30CRC, PCM31CRC
Frame structure complies with the requirement of G. 704.
(7) Testing pattern: 26-1、29-1、211-1、215-1、220-1、223-1, and artificial code
(8) Impedance of output interface:
(8.1) Non-balance 75Ω, up to G. 703
(8.2) Balance 120Ω, up to G. 703.
(9) External clock input
(9.1) Signal form: HDB3, NRZ
(9.2) Balance terminating resistance: 120Ω
Unbalance terminating resistance: 75Ω.
Balance bridging resistance: >1200Ω
Unbalance bridging resistance: >750Ω.
(10) Error code insertion: None, single, or ratio 10-1 ~ 10-7.
◆ Other Parameters
·Power supply
(1) Special power adapter
Input: AC220V 50Hz
Output: DC 9V 1A
(2) Internal rechargeable battery
4000mAh, 6V nickel-hydrogen rechargeable battery
Working time: 8 hours
Charging: 8 hours at power-off state, and 12 hours at power-on state.
·Printer: μP40-TS(CH)4 Chinese character micro-printer with standard level and serial port.
·Dimension and weight
L×W×H: 200×160×42mm
Weight: 950g
·Ambient parameters
Operation temperature: 0~40℃
Storage Temperature: -30~+70℃
Humidity: 5%~90%, non-condensing
|